{"id":25330,"date":"2025-03-11T15:30:42","date_gmt":"2025-03-11T11:30:42","guid":{"rendered":"https:\/\/airsystems.ge\/shop\/product\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/"},"modified":"2025-03-11T15:33:19","modified_gmt":"2025-03-11T11:33:19","slug":"vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war","status":"publish","type":"product","link":"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/","title":{"rendered":"Unit\u00e9 int\u00e9rieure \u00e0 conduit \u00e0 haute pression statique VRF VRV de 5,6 kW \u00e0 28 kW YVGVXH056WAR-GX YVGVXH071WAR-GX YVGVXH080WAR-GX YVGVXH090WAR-GX YVGVXH112WAR-GX YVGVXH140WAR-GX YVGVXH160WAR-GX YVGVXH226WAR-GX YVGVXH280WAR-GX YORK"},"content":{"rendered":"<ul class=\"nav hr-tabs-nav nav-alignment--center clearfix\" role=\"tablist\">\n<li class=\"hr-tabs-nav-item active in\"><a role=\"tab\" href=\"https:\/\/www.yorkvrf.com.tr\/en\/york-vrf-climate-yuksek-static-basincli-channel-type-ic-unite\/#eluida429bae2_1_0\" data-toggle=\"tab\">TECHNICAL INFORMATION<\/a><\/li>\n<li class=\"hr-tabs-nav-item \"><a role=\"tab\" href=\"https:\/\/www.yorkvrf.com.tr\/en\/york-vrf-climate-yuksek-static-basincli-channel-type-ic-unite\/#eluida429bae2_1_1\" data-toggle=\"tab\">DOCUMENTS<\/a><\/li>\n<\/ul>\n<div class=\"tab-content\">\n<div id=\"eluida429bae2_1_0\" class=\"tab-pane active in\">\n<div class=\"row tabPaneContainer \">\n<div id=\"eluid99b031ac\" class=\"eluid99b031ac col-md-12 col-sm-12 znColumnElement\">\n<div class=\"znColumnElement-innerWrapper-eluid99b031ac znColumnElement-innerWrapper znColumnElement-innerWrapper--valign-top znColumnElement-innerWrapper--halign-left \">\n<div class=\"znColumnElement-innerContent\">\n<div class=\"zn_custom_html eluid0ee6227e \">\n<table border=\"1\" width=\"852\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"156\" \/>\n<col width=\"45\" \/>\n<col width=\"53\" \/>\n<col width=\"93\" \/>\n<col span=\"5\" width=\"101\" \/><\/colgroup>\n<tbody>\n<tr>\n<td class=\"xl80\" colspan=\"3\" width=\"254\" height=\"20\"><span class=\"font6\">Model Name<\/span><\/td>\n<td class=\"xl63\" width=\"93\"><span class=\"font7\">YVGVXH056WAR&#8211;GX<\/span><\/td>\n<td class=\"xl63\" width=\"101\"><span class=\"font7\">YVGVXH071WAR&#8211;GX<\/span><\/td>\n<td class=\"xl63\" width=\"101\"><span class=\"font7\">YVGVXH080WAR&#8211;GX<\/span><\/td>\n<td class=\"xl63\" width=\"101\"><span class=\"font7\">YVGVXH090WAR&#8211;GX<\/span><\/td>\n<td class=\"xl64\" width=\"101\"><span class=\"font7\">YVGVXH112WAR&#8211;GX<\/span><\/td>\n<td class=\"xl63\" width=\"101\"><span class=\"font7\">YVGVXH140WAR&#8211;GX<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" colspan=\"2\" width=\"201\" height=\"31\"><span class=\"font8\">Power (Supply) Source ( Ph, V, Hz )<\/span><\/td>\n<td class=\"xl66\" width=\"53\"><span class=\"font8\">V \/ Ph \/ Hz<\/span><\/td>\n<td class=\"xl67\" width=\"93\"><span class=\"font5\">220~230-1-50\/60<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">220~230-1-50\/60<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">220~230-1-50\/60<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">220~230-1-50\/60<\/span><\/td>\n<td class=\"xl68\" width=\"101\"><span class=\"font5\">220~230-1-50\/60<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">220~230-1-50\/60<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font8\">Nominal Device Capacity<\/span><\/td>\n<td class=\"xl69\" width=\"53\"><span class=\"font8\">HP<\/span><\/td>\n<td class=\"xl70\">2<\/td>\n<td class=\"xl71\">2,5<\/td>\n<td class=\"xl70\">3<\/td>\n<td class=\"xl71\">3,2<\/td>\n<td class=\"xl70\">4<\/td>\n<td class=\"xl70\">5<\/td>\n<\/tr>\n<tr>\n<td class=\"xl85\" rowspan=\"2\" width=\"156\" height=\"40\"><span class=\"font6\">Capacity<\/span><\/td>\n<td class=\"xl66\" width=\"45\"><span class=\"font8\">Cooling<\/span><\/td>\n<td class=\"xl87\" rowspan=\"2\" width=\"53\"><span class=\"font8\">kW<\/span><\/td>\n<td class=\"xl72\">5,6<\/td>\n<td class=\"xl72\">7,1<\/td>\n<td class=\"xl72\">8,0<\/td>\n<td class=\"xl72\">9,0<\/td>\n<td class=\"xl72\">11,2<\/td>\n<td class=\"xl72\">14,0<\/td>\n<\/tr>\n<tr>\n<td class=\"xl66\" width=\"45\" height=\"20\"><span class=\"font8\">Heating<\/span><\/td>\n<td class=\"xl71\">7,1<\/td>\n<td class=\"xl71\">8,0<\/td>\n<td class=\"xl71\">9,0<\/td>\n<td class=\"xl71\">10,0<\/td>\n<td class=\"xl71\">12,5<\/td>\n<td class=\"xl71\">16,0<\/td>\n<\/tr>\n<tr>\n<td class=\"xl89\" rowspan=\"2\" width=\"156\" height=\"40\"><span class=\"font8\">Capacity<\/span><\/td>\n<td class=\"xl66\" width=\"45\"><span class=\"font8\">Cooling<\/span><\/td>\n<td class=\"xl91\" rowspan=\"2\" width=\"53\"><span class=\"font8\">Btu\/H<\/span><\/td>\n<td class=\"xl73\">19100<\/td>\n<td class=\"xl73\">24200<\/td>\n<td class=\"xl73\">27300<\/td>\n<td class=\"xl73\">30700<\/td>\n<td class=\"xl73\">38200<\/td>\n<td class=\"xl73\">47700<\/td>\n<\/tr>\n<tr>\n<td class=\"xl66\" width=\"45\" height=\"20\"><span class=\"font8\">Heating<\/span><\/td>\n<td class=\"xl70\">21500<\/td>\n<td class=\"xl70\">27300<\/td>\n<td class=\"xl70\">30700<\/td>\n<td class=\"xl70\">34100<\/td>\n<td class=\"xl70\">42600<\/td>\n<td class=\"xl70\">54600<\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font8\">Absorbed Power<\/span><\/td>\n<td class=\"xl69\" width=\"53\"><span class=\"font8\">W<\/span><\/td>\n<td class=\"xl73\">450<\/td>\n<td class=\"xl73\">450<\/td>\n<td class=\"xl73\">450<\/td>\n<td class=\"xl73\">560<\/td>\n<td class=\"xl73\">560<\/td>\n<td class=\"xl73\">560<\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font8\">Working Current<\/span><\/td>\n<td class=\"xl69\" width=\"53\"><span class=\"font8\">kW<\/span><\/td>\n<td class=\"xl74\">2,05<\/td>\n<td class=\"xl74\">2,05<\/td>\n<td class=\"xl74\">2,05<\/td>\n<td class=\"xl71\">2,6<\/td>\n<td class=\"xl71\">2,6<\/td>\n<td class=\"xl71\">2,6<\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font8\">External Static Pressure<\/span><\/td>\n<td class=\"xl69\" width=\"53\"><span class=\"font8\">Pa<\/span><\/td>\n<td class=\"xl67\" width=\"93\"><span class=\"font5\">50 ~ 196<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">50 ~ 196<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">50 ~ 196<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">50 ~ 196<\/span><\/td>\n<td class=\"xl75\" width=\"101\"><span class=\"font5\">50 ~ 196<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">50 ~ 196<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font8\">Air Flow (High \/ Medium \/ Low)<\/span><\/td>\n<td class=\"xl76\" width=\"53\"><span class=\"font8\">m<\/span><span class=\"font9\"><sup>3<\/sup><\/span><span class=\"font8\">\/h<\/span><\/td>\n<td class=\"xl77\" width=\"93\"><span class=\"font5\">1500 \/ 1357 \/ 1089<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">1500 \/ 1357 \/ 1089<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">1500 \/ 1357 \/ 1089<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">1560 \/ 1412 \/ 1162<\/span><\/td>\n<td class=\"xl78\" width=\"101\"><span class=\"font5\">1600 \/ 1448 \/ 1162<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">2100 \/ 1901 \/ 1525<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font8\">Volume ( High \/ Medium \/ Low )<\/span><\/td>\n<td class=\"xl69\" width=\"53\"><span class=\"font8\">dB(A)<\/span><\/td>\n<td class=\"xl67\" width=\"93\"><span class=\"font5\">42 \/ 40 \/ 38<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">42 \/ 40 \/ 38<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">42 \/ 40 \/ 38<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">45 \/ 43 \/ 40<\/span><\/td>\n<td class=\"xl75\" width=\"101\"><span class=\"font5\">45 \/ 43 \/ 40<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">45 \/ 43 \/ 40<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl85\" rowspan=\"3\" width=\"156\" height=\"60\"><span class=\"font6\">Body Dimensions<\/span><\/td>\n<td class=\"xl66\" width=\"45\"><span class=\"font8\">Height<\/span><\/td>\n<td class=\"xl87\" rowspan=\"3\" width=\"53\"><span class=\"font8\">mm<\/span><\/td>\n<td class=\"xl70\">360<\/td>\n<td class=\"xl70\">360<\/td>\n<td class=\"xl70\">360<\/td>\n<td class=\"xl70\">360<\/td>\n<td class=\"xl70\">360<\/td>\n<td class=\"xl70\">360<\/td>\n<\/tr>\n<tr>\n<td class=\"xl66\" width=\"45\" height=\"20\"><span class=\"font8\">Width<\/span><\/td>\n<td class=\"xl73\">970<\/td>\n<td class=\"xl73\">970<\/td>\n<td class=\"xl73\">970<\/td>\n<td class=\"xl73\">1350<\/td>\n<td class=\"xl73\">1350<\/td>\n<td class=\"xl73\">1350<\/td>\n<\/tr>\n<tr>\n<td class=\"xl66\" width=\"45\" height=\"20\"><span class=\"font8\">Depth<\/span><\/td>\n<td class=\"xl70\">906<\/td>\n<td class=\"xl70\">906<\/td>\n<td class=\"xl70\">906<\/td>\n<td class=\"xl70\">875<\/td>\n<td class=\"xl70\">875<\/td>\n<td class=\"xl70\">875<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"156\" height=\"20\"><span class=\"font8\">Weight<\/span><\/td>\n<td class=\"xl66\" width=\"45\"><span class=\"font8\">Body<\/span><\/td>\n<td class=\"xl69\" width=\"53\"><span class=\"font8\">kg<\/span><\/td>\n<td class=\"xl73\">56<\/td>\n<td class=\"xl73\">56<\/td>\n<td class=\"xl73\">56<\/td>\n<td class=\"xl73\">62<\/td>\n<td class=\"xl73\">62<\/td>\n<td class=\"xl73\">62<\/td>\n<\/tr>\n<tr>\n<td class=\"xl89\" rowspan=\"2\" width=\"156\" height=\"40\"><span class=\"font8\">Copper Pipe Connection Diameters<\/span><\/td>\n<td class=\"xl66\" width=\"45\"><span class=\"font8\">Liquid<\/span><\/td>\n<td class=\"xl87\" rowspan=\"2\" width=\"53\"><span class=\"font8\">mm<\/span><\/td>\n<td class=\"xl77\" width=\"93\"><span class=\"font5\">\u00d8 6,35<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">\u00d8 9,52<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">\u00d8 9,52<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">\u00d8 9,52<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">\u00d8 9,52<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">\u00d8 9,52<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl66\" width=\"45\" height=\"20\"><span class=\"font8\">Gaz<\/span><\/td>\n<td class=\"xl67\" width=\"93\"><span class=\"font5\">\u00d8 12,7<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">\u00d8 15.88<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">\u00d8 15.88<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">\u00d8 15.88<\/span><\/td>\n<td class=\"xl75\" width=\"101\"><span class=\"font5\">\u00d8 15.88<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">\u00d8 15.88<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl89\" rowspan=\"2\" width=\"156\" height=\"40\"><span class=\"font8\">Channel Connection Dimensions<\/span><\/td>\n<td class=\"xl66\" width=\"45\"><span class=\"font8\">Blowing<\/span><\/td>\n<td class=\"xl95\" rowspan=\"2\" width=\"53\"><span class=\"font8\">( G x Y )<\/span><br \/>\n<span class=\"font8\">mm<\/span><\/td>\n<td class=\"xl77\" width=\"93\"><span class=\"font5\">600 x 255<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">600 x 255<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">600 x 255<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">855 x 255<\/span><\/td>\n<td class=\"xl79\" width=\"101\"><span class=\"font5\">855 x 255<\/span><\/td>\n<td class=\"xl77\" width=\"101\"><span class=\"font5\">855 x 255<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl66\" width=\"45\" height=\"20\"><span class=\"font8\">suction<\/span><\/td>\n<td class=\"xl67\" width=\"93\"><span class=\"font5\">750 x 255<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">750 x 255<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">750 x 255<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">1105 x 255<\/span><\/td>\n<td class=\"xl75\" width=\"101\"><span class=\"font5\">1105 x 255<\/span><\/td>\n<td class=\"xl67\" width=\"101\"><span class=\"font5\">1105 x 255<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font8\">Drain Mouth Outlet Diameter<\/span><\/td>\n<td class=\"xl69\" width=\"53\"><span class=\"font8\">mm<\/span><\/td>\n<td class=\"xl70\">30<\/td>\n<td class=\"xl70\">30<\/td>\n<td class=\"xl70\">30<\/td>\n<td class=\"xl70\">30<\/td>\n<td class=\"xl70\">30<\/td>\n<td class=\"xl70\">30<\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" colspan=\"3\" width=\"254\" height=\"20\"><span class=\"font8\">Drain Pump &#8211; Head<\/span><\/td>\n<td class=\"xl98\" colspan=\"6\" width=\"598\"><span class=\"font5\">Optional &#8211; KT-NP01<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table border=\"1\" width=\"671\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"156\" \/>\n<col span=\"2\" width=\"45\" \/>\n<col width=\"147\" \/>\n<col span=\"2\" width=\"139\" \/><\/colgroup>\n<tbody>\n<tr>\n<td class=\"xl74\" colspan=\"3\" width=\"246\" height=\"20\"><span class=\"font6\">Model Name<\/span><\/td>\n<td class=\"xl63\" width=\"147\"><span class=\"font6\">YVGVXH160WAR&#8211;GX<\/span><\/td>\n<td class=\"xl63\" width=\"139\"><span class=\"font6\">YVGVXH226WAR&#8211;GX<\/span><\/td>\n<td class=\"xl63\" width=\"139\"><span class=\"font6\">YVGVXH280WAR&#8211;GX<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl77\" colspan=\"2\" width=\"201\" height=\"31\"><span class=\"font7\">Power (Supply) Source ( Ph, V, Hz )<\/span><\/td>\n<td class=\"xl65\" width=\"45\"><span class=\"font7\">V \/ Ph \/ Hz<\/span><\/td>\n<td class=\"xl66\" width=\"147\"><span class=\"font5\">220~230-1-50\/60<\/span><\/td>\n<td class=\"xl66\" width=\"139\"><span class=\"font5\">220~230-1-50\/60<\/span><\/td>\n<td class=\"xl66\" width=\"139\"><span class=\"font5\">220~230-1-50\/60<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl77\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font7\">Nominal Device Capacity<\/span><\/td>\n<td class=\"xl67\" width=\"45\"><span class=\"font7\">HP<\/span><\/td>\n<td class=\"xl68\">6<\/td>\n<td class=\"xl68\">8<\/td>\n<td class=\"xl68\">10<\/td>\n<\/tr>\n<tr>\n<td class=\"xl79\" rowspan=\"2\" width=\"156\" height=\"40\"><span class=\"font6\">Capacity<\/span><\/td>\n<td class=\"xl65\" width=\"45\"><span class=\"font7\">Cooling<\/span><\/td>\n<td class=\"xl81\" rowspan=\"2\" width=\"45\"><span class=\"font7\">kW<\/span><\/td>\n<td class=\"xl69\">15,8<\/td>\n<td class=\"xl69\">22,6<\/td>\n<td class=\"xl69\">28,0<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"45\" height=\"20\"><span class=\"font7\">Heating<\/span><\/td>\n<td class=\"xl70\">18,0<\/td>\n<td class=\"xl70\">25,0<\/td>\n<td class=\"xl70\">31,7<\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" rowspan=\"2\" width=\"156\" height=\"40\"><span class=\"font7\">Capacity<\/span><\/td>\n<td class=\"xl65\" width=\"45\"><span class=\"font7\">Cooling<\/span><\/td>\n<td class=\"xl85\" rowspan=\"2\" width=\"45\"><span class=\"font7\">Btu\/H<\/span><\/td>\n<td class=\"xl71\">54000<\/td>\n<td class=\"xl71\">77100<\/td>\n<td class=\"xl71\">95500<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"45\" height=\"20\"><span class=\"font7\">Heating<\/span><\/td>\n<td class=\"xl68\">61400<\/td>\n<td class=\"xl68\">81300<\/td>\n<td class=\"xl68\">108000<\/td>\n<\/tr>\n<tr>\n<td class=\"xl77\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font7\">Absorbed Power<\/span><\/td>\n<td class=\"xl67\" width=\"45\"><span class=\"font7\">W<\/span><\/td>\n<td class=\"xl71\">560<\/td>\n<td class=\"xl71\">1110<\/td>\n<td class=\"xl71\">1110<\/td>\n<\/tr>\n<tr>\n<td class=\"xl77\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font7\">Working Current<\/span><\/td>\n<td class=\"xl67\" width=\"45\"><span class=\"font7\">kW<\/span><\/td>\n<td class=\"xl70\">2,6<\/td>\n<td class=\"xl70\">5,0<\/td>\n<td class=\"xl70\">5,0<\/td>\n<\/tr>\n<tr>\n<td class=\"xl77\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font7\">External Static Pressure<\/span><\/td>\n<td class=\"xl67\" width=\"45\"><span class=\"font7\">Pa<\/span><\/td>\n<td class=\"xl66\" width=\"147\"><span class=\"font5\">50 ~ 196<\/span><\/td>\n<td class=\"xl66\" width=\"139\"><span class=\"font5\">50 ~ 196<\/span><\/td>\n<td class=\"xl66\" width=\"139\"><span class=\"font5\">50 ~ 196<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl77\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font7\">Air Flow (High \/ Medium \/ Low)<\/span><\/td>\n<td class=\"xl72\" width=\"45\"><span class=\"font7\">m<\/span><span class=\"font8\"><sup>3<\/sup><\/span><span class=\"font7\">\/h<\/span><\/td>\n<td class=\"xl73\" width=\"147\"><span class=\"font5\">2100 \/ 1901 \/ 1525<\/span><\/td>\n<td class=\"xl73\" width=\"139\"><span class=\"font5\">4050 \/ 3255 \/ 2612<\/span><\/td>\n<td class=\"xl73\" width=\"139\"><span class=\"font5\">4050 \/ 3255 \/ 2612<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl77\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font7\">Volume ( High \/ Medium \/ Low )<\/span><\/td>\n<td class=\"xl67\" width=\"45\"><span class=\"font7\">dB(A)<\/span><\/td>\n<td class=\"xl66\" width=\"147\"><span class=\"font5\">45 \/ 43 \/ 40<\/span><\/td>\n<td class=\"xl66\" width=\"139\"><span class=\"font5\">54 \/ 51 \/ 49<\/span><\/td>\n<td class=\"xl66\" width=\"139\"><span class=\"font5\">54 \/ 51 \/ 49<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl79\" rowspan=\"3\" width=\"156\" height=\"60\"><span class=\"font6\">Body Dimensions<\/span><\/td>\n<td class=\"xl65\" width=\"45\"><span class=\"font7\">Height<\/span><\/td>\n<td class=\"xl81\" rowspan=\"3\" width=\"45\"><span class=\"font7\">mm<\/span><\/td>\n<td class=\"xl68\">360<\/td>\n<td class=\"xl68\">360<\/td>\n<td class=\"xl68\">360<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"45\" height=\"20\"><span class=\"font7\">Width<\/span><\/td>\n<td class=\"xl71\">1350<\/td>\n<td class=\"xl71\">1720<\/td>\n<td class=\"xl71\">1720<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"45\" height=\"20\"><span class=\"font7\">Depth<\/span><\/td>\n<td class=\"xl68\">875<\/td>\n<td class=\"xl68\">880<\/td>\n<td class=\"xl68\">880<\/td>\n<\/tr>\n<tr>\n<td class=\"xl64\" width=\"156\" height=\"20\"><span class=\"font7\">Weight<\/span><\/td>\n<td class=\"xl65\" width=\"45\"><span class=\"font7\">Body<\/span><\/td>\n<td class=\"xl67\" width=\"45\"><span class=\"font7\">kg<\/span><\/td>\n<td class=\"xl71\">62<\/td>\n<td class=\"xl71\">92<\/td>\n<td class=\"xl71\">92<\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" rowspan=\"2\" width=\"156\" height=\"40\"><span class=\"font7\">Copper Pipe Connection Diameters<\/span><\/td>\n<td class=\"xl65\" width=\"45\"><span class=\"font7\">Liquid<\/span><\/td>\n<td class=\"xl81\" rowspan=\"2\" width=\"45\"><span class=\"font7\">mm<\/span><\/td>\n<td class=\"xl73\" width=\"147\"><span class=\"font5\">\u00d8 9,52<\/span><\/td>\n<td class=\"xl73\" width=\"139\"><span class=\"font5\">\u00d8 9,52<\/span><\/td>\n<td class=\"xl73\" width=\"139\"><span class=\"font5\">\u00d8 9,52<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"45\" height=\"20\"><span class=\"font7\">Gaz<\/span><\/td>\n<td class=\"xl66\" width=\"147\"><span class=\"font5\">\u00d8 15.88<\/span><\/td>\n<td class=\"xl66\" width=\"139\"><span class=\"font5\">\u00d8 25.4<\/span><\/td>\n<td class=\"xl66\" width=\"139\"><span class=\"font5\">\u00d8 25.4<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl83\" rowspan=\"2\" width=\"156\" height=\"40\"><span class=\"font7\">Channel Connection Dimensions<\/span><\/td>\n<td class=\"xl65\" width=\"45\"><span class=\"font7\">Blowing<\/span><\/td>\n<td class=\"xl89\" rowspan=\"2\" width=\"45\"><span class=\"font7\">( G x Y )<\/span><br \/>\n<span class=\"font7\">mm<\/span><\/td>\n<td class=\"xl73\" width=\"147\"><span class=\"font5\">1510 x 255<\/span><\/td>\n<td class=\"xl73\" width=\"139\"><span class=\"font5\">1510 x 255<\/span><\/td>\n<td class=\"xl73\" width=\"139\"><span class=\"font5\">1510 x 255<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"45\" height=\"20\"><span class=\"font7\">suction<\/span><\/td>\n<td class=\"xl66\" width=\"147\"><span class=\"font5\">1510 x 255<\/span><\/td>\n<td class=\"xl66\" width=\"139\"><span class=\"font5\">1510 x 255<\/span><\/td>\n<td class=\"xl66\" width=\"139\"><span class=\"font5\">1510 x 255<\/span><\/td>\n<\/tr>\n<tr>\n<td class=\"xl77\" colspan=\"2\" width=\"201\" height=\"20\"><span class=\"font7\">Drain Mouth Outlet Diameter<\/span><\/td>\n<td class=\"xl67\" width=\"45\"><span class=\"font7\">mm<\/span><\/td>\n<td class=\"xl70\">32,5<\/td>\n<td class=\"xl70\">32,5<\/td>\n<td class=\"xl70\">32,5<\/td>\n<\/tr>\n<tr>\n<td class=\"xl77\" colspan=\"3\" width=\"246\" height=\"20\"><span class=\"font7\">Drain Pump &#8211; Head<\/span><\/td>\n<td class=\"xl92\" colspan=\"3\" width=\"425\"><span class=\"font5\">Optional &#8211; KT-NP01<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Conception \u00e0 haute pression statique<br \/>\n\u2013 Pression statique externe max. 196 Pa<br \/>\n\u2013 Pression statique s\u00e9lectionnable 100 ou 196 Pa<br \/>\n\u2022 R\u00e9glage ind\u00e9pendant du conduit de sortie d&rsquo;air<br \/>\n\u2013 Les sorties d&rsquo;air et le style de montage peuvent \u00eatre r\u00e9gl\u00e9s selon les besoins<br \/>\n\u2022 Commande filaire standard, commande sans fil en option<\/p>\n<p>&nbsp;<\/p>\n<table width=\"267\">\n<tbody>\n<tr>\n<td width=\"135\">YVGVXH056WAR-GX<\/td>\n<td width=\"64\">5.6<\/td>\n<td width=\"68\">\u00a0\u00a0\u00a0\u00a0 1,457 \u20be<\/td>\n<\/tr>\n<tr>\n<td>YVGVXH071WAR-GX<\/td>\n<td>7.1<\/td>\n<td>\u00a0\u00a0\u00a0\u00a0 1,519 \u20be<\/td>\n<\/tr>\n<tr>\n<td>YVGVXH080WAR-GX<\/td>\n<td>8.0<\/td>\n<td>\u00a0\u00a0\u00a0\u00a0 1,612 \u20be<\/td>\n<\/tr>\n<tr>\n<td>YVGVXH090WAR-GX<\/td>\n<td>9.0<\/td>\n<td>\u00a0\u00a0\u00a0\u00a0 1,736 \u20be<\/td>\n<\/tr>\n<tr>\n<td>YVGVXH112WAR-GX<\/td>\n<td>11.2<\/td>\n<td>\u00a0\u00a0\u00a0\u00a0 1,798 \u20be<\/td>\n<\/tr>\n<tr>\n<td>YVGVXH140WAR-GX<\/td>\n<td>14.0<\/td>\n<td>\u00a0\u00a0\u00a0\u00a0 1,829 \u20be<\/td>\n<\/tr>\n<tr>\n<td>YVGVXH160WAR-GX<\/td>\n<td>16.0<\/td>\n<td>\u00a0\u00a0\u00a0\u00a0 2,232 \u20be<\/td>\n<\/tr>\n<tr>\n<td>YVGVXH226WAR-GX<\/td>\n<td>22.6<\/td>\n<td>\u00a0\u00a0\u00a0\u00a0 2,852 \u20be<\/td>\n<\/tr>\n<tr>\n<td>YVGVXH280WAR-GX<\/td>\n<td>28.0<\/td>\n<td>\u00a0\u00a0\u00a0\u00a0 2,930 \u20be<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":25324,"template":"","meta":[],"product_brand":[],"product_cat":[705,1074],"product_tag":[],"class_list":{"0":"post-25330","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-climatiseur","7":"product_cat-vrf-interieure-unite-vrv-fr","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.1.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Unit\u00e9 int\u00e9rieure \u00e0 conduit \u00e0 haute pression statique VRF VRV de 5,6 kW \u00e0 28 kW YVGVXH056WAR-GX YVGVXH071WAR-GX YVGVXH080WAR-GX YVGVXH090WAR-GX YVGVXH112WAR-GX YVGVXH140WAR-GX YVGVXH160WAR-GX YVGVXH226WAR-GX YVGVXH280WAR-GX YORK - AirRent.ge<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Unit\u00e9 int\u00e9rieure \u00e0 conduit \u00e0 haute pression statique VRF VRV de 5,6 kW \u00e0 28 kW YVGVXH056WAR-GX YVGVXH071WAR-GX YVGVXH080WAR-GX YVGVXH090WAR-GX YVGVXH112WAR-GX YVGVXH140WAR-GX YVGVXH160WAR-GX YVGVXH226WAR-GX YVGVXH280WAR-GX YORK - AirRent.ge\" \/>\n<meta property=\"og:description\" content=\"Conception \u00e0 haute pression statique \u2013 Pression statique externe max. 196 Pa \u2013 Pression statique s\u00e9lectionnable 100 ou 196 Pa \u2022 R\u00e9glage ind\u00e9pendant du conduit de sortie d&#039;air \u2013 Les sorties d&#039;air et le style de montage peuvent \u00eatre r\u00e9gl\u00e9s selon les besoins \u2022 Commande filaire standard, commande sans fil en option  &nbsp;    YVGVXH056WAR-GX 5.6 \u00a0\u00a0\u00a0\u00a0 1,457 \u20be   YVGVXH071WAR-GX 7.1 \u00a0\u00a0\u00a0\u00a0 1,519 \u20be   YVGVXH080WAR-GX 8.0 \u00a0\u00a0\u00a0\u00a0 1,612 \u20be   YVGVXH090WAR-GX 9.0 \u00a0\u00a0\u00a0\u00a0 1,736 \u20be   YVGVXH112WAR-GX 11.2 \u00a0\u00a0\u00a0\u00a0 1,798 \u20be   YVGVXH140WAR-GX 14.0 \u00a0\u00a0\u00a0\u00a0 1,829 \u20be   YVGVXH160WAR-GX 16.0 \u00a0\u00a0\u00a0\u00a0 2,232 \u20be   YVGVXH226WAR-GX 22.6 \u00a0\u00a0\u00a0\u00a0 2,852 \u20be   YVGVXH280WAR-GX 28.0 \u00a0\u00a0\u00a0\u00a0 2,930 \u20be\" \/>\n<meta property=\"og:url\" content=\"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/\" \/>\n<meta property=\"og:site_name\" content=\"AirRent.ge\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-11T11:33:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/airrent.ge\/wp-content\/uploads\/2025\/03\/york-vrf-klima-yuksek-statik-basincli-kanalli-tipi-ic-unite-YVGVXHWAR-GX-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1890\" \/>\n\t<meta property=\"og:image:height\" content=\"1417\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/\",\"url\":\"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/\",\"name\":\"Unit\u00e9 int\u00e9rieure \u00e0 conduit \u00e0 haute pression statique VRF VRV de 5,6 kW \u00e0 28 kW YVGVXH056WAR-GX YVGVXH071WAR-GX YVGVXH080WAR-GX YVGVXH090WAR-GX YVGVXH112WAR-GX YVGVXH140WAR-GX YVGVXH160WAR-GX YVGVXH226WAR-GX YVGVXH280WAR-GX YORK - AirRent.ge\",\"isPartOf\":{\"@id\":\"https:\/\/airrent.ge\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/airrent.ge\/wp-content\/uploads\/2025\/03\/york-vrf-klima-yuksek-statik-basincli-kanalli-tipi-ic-unite-YVGVXHWAR-GX-1.webp\",\"datePublished\":\"2025-03-11T11:30:42+00:00\",\"dateModified\":\"2025-03-11T11:33:19+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/#primaryimage\",\"url\":\"https:\/\/airrent.ge\/wp-content\/uploads\/2025\/03\/york-vrf-klima-yuksek-statik-basincli-kanalli-tipi-ic-unite-YVGVXHWAR-GX-1.webp\",\"contentUrl\":\"https:\/\/airrent.ge\/wp-content\/uploads\/2025\/03\/york-vrf-klima-yuksek-statik-basincli-kanalli-tipi-ic-unite-YVGVXHWAR-GX-1.webp\",\"width\":1890,\"height\":1417},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/airrent.ge\/fr\/home\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/airrent.ge\/fr\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Unit\u00e9 int\u00e9rieure \u00e0 conduit \u00e0 haute pression statique VRF VRV de 5,6 kW \u00e0 28 kW YVGVXH056WAR-GX YVGVXH071WAR-GX YVGVXH080WAR-GX YVGVXH090WAR-GX YVGVXH112WAR-GX YVGVXH140WAR-GX YVGVXH160WAR-GX YVGVXH226WAR-GX YVGVXH280WAR-GX YORK\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/airrent.ge\/#website\",\"url\":\"https:\/\/airrent.ge\/\",\"name\":\"airrent.ge\",\"description\":\"Rental Services\",\"publisher\":{\"@id\":\"https:\/\/airrent.ge\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/airrent.ge\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/airrent.ge\/#organization\",\"name\":\"airrent.ge\",\"url\":\"https:\/\/airrent.ge\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/airrent.ge\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/airrent.ge\/wp-content\/uploads\/2026\/03\/airrent.png\",\"contentUrl\":\"https:\/\/airrent.ge\/wp-content\/uploads\/2026\/03\/airrent.png\",\"width\":1536,\"height\":1024,\"caption\":\"airrent.ge\"},\"image\":{\"@id\":\"https:\/\/airrent.ge\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Unit\u00e9 int\u00e9rieure \u00e0 conduit \u00e0 haute pression statique VRF VRV de 5,6 kW \u00e0 28 kW YVGVXH056WAR-GX YVGVXH071WAR-GX YVGVXH080WAR-GX YVGVXH090WAR-GX YVGVXH112WAR-GX YVGVXH140WAR-GX YVGVXH160WAR-GX YVGVXH226WAR-GX YVGVXH280WAR-GX YORK - AirRent.ge","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/","og_locale":"fr_FR","og_type":"article","og_title":"Unit\u00e9 int\u00e9rieure \u00e0 conduit \u00e0 haute pression statique VRF VRV de 5,6 kW \u00e0 28 kW YVGVXH056WAR-GX YVGVXH071WAR-GX YVGVXH080WAR-GX YVGVXH090WAR-GX YVGVXH112WAR-GX YVGVXH140WAR-GX YVGVXH160WAR-GX YVGVXH226WAR-GX YVGVXH280WAR-GX YORK - AirRent.ge","og_description":"Conception \u00e0 haute pression statique \u2013 Pression statique externe max. 196 Pa \u2013 Pression statique s\u00e9lectionnable 100 ou 196 Pa \u2022 R\u00e9glage ind\u00e9pendant du conduit de sortie d'air \u2013 Les sorties d'air et le style de montage peuvent \u00eatre r\u00e9gl\u00e9s selon les besoins \u2022 Commande filaire standard, commande sans fil en option  &nbsp;    YVGVXH056WAR-GX 5.6 \u00a0\u00a0\u00a0\u00a0 1,457 \u20be   YVGVXH071WAR-GX 7.1 \u00a0\u00a0\u00a0\u00a0 1,519 \u20be   YVGVXH080WAR-GX 8.0 \u00a0\u00a0\u00a0\u00a0 1,612 \u20be   YVGVXH090WAR-GX 9.0 \u00a0\u00a0\u00a0\u00a0 1,736 \u20be   YVGVXH112WAR-GX 11.2 \u00a0\u00a0\u00a0\u00a0 1,798 \u20be   YVGVXH140WAR-GX 14.0 \u00a0\u00a0\u00a0\u00a0 1,829 \u20be   YVGVXH160WAR-GX 16.0 \u00a0\u00a0\u00a0\u00a0 2,232 \u20be   YVGVXH226WAR-GX 22.6 \u00a0\u00a0\u00a0\u00a0 2,852 \u20be   YVGVXH280WAR-GX 28.0 \u00a0\u00a0\u00a0\u00a0 2,930 \u20be","og_url":"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/","og_site_name":"AirRent.ge","article_modified_time":"2025-03-11T11:33:19+00:00","og_image":[{"width":1890,"height":1417,"url":"https:\/\/airrent.ge\/wp-content\/uploads\/2025\/03\/york-vrf-klima-yuksek-statik-basincli-kanalli-tipi-ic-unite-YVGVXHWAR-GX-1.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/","url":"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/","name":"Unit\u00e9 int\u00e9rieure \u00e0 conduit \u00e0 haute pression statique VRF VRV de 5,6 kW \u00e0 28 kW YVGVXH056WAR-GX YVGVXH071WAR-GX YVGVXH080WAR-GX YVGVXH090WAR-GX YVGVXH112WAR-GX YVGVXH140WAR-GX YVGVXH160WAR-GX YVGVXH226WAR-GX YVGVXH280WAR-GX YORK - AirRent.ge","isPartOf":{"@id":"https:\/\/airrent.ge\/#website"},"primaryImageOfPage":{"@id":"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/#primaryimage"},"image":{"@id":"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/#primaryimage"},"thumbnailUrl":"https:\/\/airrent.ge\/wp-content\/uploads\/2025\/03\/york-vrf-klima-yuksek-statik-basincli-kanalli-tipi-ic-unite-YVGVXHWAR-GX-1.webp","datePublished":"2025-03-11T11:30:42+00:00","dateModified":"2025-03-11T11:33:19+00:00","breadcrumb":{"@id":"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/#primaryimage","url":"https:\/\/airrent.ge\/wp-content\/uploads\/2025\/03\/york-vrf-klima-yuksek-statik-basincli-kanalli-tipi-ic-unite-YVGVXHWAR-GX-1.webp","contentUrl":"https:\/\/airrent.ge\/wp-content\/uploads\/2025\/03\/york-vrf-klima-yuksek-statik-basincli-kanalli-tipi-ic-unite-YVGVXHWAR-GX-1.webp","width":1890,"height":1417},{"@type":"BreadcrumbList","@id":"https:\/\/airrent.ge\/fr\/produit\/vrf-vrv-fan-coil-high-static-pressure-duct-type-indoor-unit-5-6-kw-to-28-kw-yvgvxh056war-gx-yvgvxh071war-gx-yvgvxh080war-gx-yvgvxh090war-gx-yvgvxh112war-gx-yvgvxh140war-gx-yvgvxh160war-gx-yvgvxh226war\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/airrent.ge\/fr\/home\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/airrent.ge\/fr\/products\/"},{"@type":"ListItem","position":3,"name":"Unit\u00e9 int\u00e9rieure \u00e0 conduit \u00e0 haute pression statique VRF VRV de 5,6 kW \u00e0 28 kW YVGVXH056WAR-GX YVGVXH071WAR-GX YVGVXH080WAR-GX YVGVXH090WAR-GX YVGVXH112WAR-GX YVGVXH140WAR-GX YVGVXH160WAR-GX YVGVXH226WAR-GX YVGVXH280WAR-GX YORK"}]},{"@type":"WebSite","@id":"https:\/\/airrent.ge\/#website","url":"https:\/\/airrent.ge\/","name":"airrent.ge","description":"Rental Services","publisher":{"@id":"https:\/\/airrent.ge\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/airrent.ge\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/airrent.ge\/#organization","name":"airrent.ge","url":"https:\/\/airrent.ge\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/airrent.ge\/#\/schema\/logo\/image\/","url":"https:\/\/airrent.ge\/wp-content\/uploads\/2026\/03\/airrent.png","contentUrl":"https:\/\/airrent.ge\/wp-content\/uploads\/2026\/03\/airrent.png","width":1536,"height":1024,"caption":"airrent.ge"},"image":{"@id":"https:\/\/airrent.ge\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/airrent.ge\/fr\/wp-json\/wp\/v2\/product\/25330","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/airrent.ge\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/airrent.ge\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/airrent.ge\/fr\/wp-json\/wp\/v2\/media\/25324"}],"wp:attachment":[{"href":"https:\/\/airrent.ge\/fr\/wp-json\/wp\/v2\/media?parent=25330"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/airrent.ge\/fr\/wp-json\/wp\/v2\/product_brand?post=25330"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/airrent.ge\/fr\/wp-json\/wp\/v2\/product_cat?post=25330"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/airrent.ge\/fr\/wp-json\/wp\/v2\/product_tag?post=25330"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}